Op maat gemaakte kunststofonderdelen: van prototype tot productie — Vraag vandaag nog uw offerte aan. WhatsApp +86 156 0682 1288 [email protected]

Bio-based & specialty

Custom Glass-Filled Composites Injection Molding Factory

Glass-fibre and mineral filled composites are thermoplastics (PA, PP, PBT, PPS) reinforced with glass fibre, mineral flakes or a mixture. The filler changes the shrinkage, the heat resistance and the wear behaviour -the steel moves up a family because glass is abrasive.

Last updated

Krimp
0.2-.0%
Melt
200-20°C
Mould
60-40°C

Belangrijkste kenmerken

Krimp
0.2-.0 %
Mould
60-40 °C
Abrasiveness
High at gate and vent

Typical values for grade selection. Confirm the exact grade against the resin supplier TDS before releasing a tool or a tolerance.

Side by side

MateriaalShrinkage %Melt °CMould °CAbrasivenessUsual steel
GF-Composite0.2-.0200-2060-40HoogH13 / S136
PLA0.2-.5180-1030-0LaagP20
PBAT1.0-2.5180-0025-0LaagP20
PA111.0-2.5220-4040-60Medium718H
PA121.5-2.0210-3040-60Medium718H

What GF-Composite actually is

Glass-fibre and mineral filled composites are thermoplastics (PA, PP, PBT, PPS) reinforced with glass fibre, mineral flakes or a mixture. The filler changes the shrinkage, the heat resistance and the wear behaviour -the steel moves up a family because glass is abrasive.

Chemically, Glass-Filled belongs to the Glass-fibre and mineral filled composites - bio-specialty family. The polymer chain structure — modified with specialty co-monomers or fillers — is what sets its shrinkage behaviour, temperature ceiling and melt flow. Like every thermoplastic, its properties are the result of processing history as much as of the resin grade itself: slow cooling increases crystallinity and brittleness, fast cooling locks in an amorphous structure and a different shrink. Resin suppliers offer Glass-Filled in commodity, reinforced and specialty grades, and the first selection step is to pick the right family before settling on a specific TDS.

Processing window

The typical process window runs with a melt temperature around 200-20 °C and a mould temperature around 60-40 °C. Inside that band the resin fills, packs and ejects predictably. Outside it, the failure modes are specific rather than vague.

Above the recommended melt temperature, Glass-Filled can degrade thermally — the symptom is silver streaking, a mottled surface and a measurable loss of impact strength that the part carries into service. Long residence time in a large barrel running small shots is as damaging as a direct temperature overshoot, because the resin sits at temperature longer than intended. Below the lower bound, the melt freezes before it has fully packed the cavity: the part shows visible weld lines, flow marks around the gate and a surface that reads differently across the flow path.

Drying is a standard preparation step. Glass-Filled absorbs moisture very little, so drying is usually unnecessary unless the resin has been stored in a particularly humid environment or has become contaminated. When in doubt, a quick hopper dry adds schedule but removes a common yield risk. The resin supplier TDS always takes precedence over a generic figure on drying and moisture content.

Shrinkage and dimensional tolerance

Design the tool to 0.2-.0 % shrinkage and expect the actual figure to sit at a specific point inside that band rather than the middle. The value is set by wall thickness, flow length, gate position, packing pressure, hold time and mould temperature. Thick sections shrink more because there is more melt to contract; long flow paths lose pressure before the cavity is packed, so the far end shrinks more than the gate end.

Glass-Filled is amorphous, which means shrinkage is comparatively even in flow and cross-flow directions. That is why a single global shrink factor is a starting point, not an answer. On a long, thin part, the difference between the gate end and the far end can exceed the tolerance you are trying to hold. The fix is either to gate where the pressure can reach the whole part, to add a packing profile, or to accept that the tight tolerance belongs on the features near the gate and not on the overall length.

We cut the first sample with a nominal allowance and measure the first shots on a CMM before touching the cavity. Correcting a tool from measured parts is cheaper and more reliable than correcting it from a data-sheet range, and the measurement record is what the next tool for the same grade starts from.

What Glass-Filled asks of the mould steel

The default steel family for Glass-Filled is H13 / S136. That choice is driven by three properties in combination: abrasiveness, mould temperature and the risk of chemical attack.

Abrasiveness is Hoog. The resin — or its glass or mineral filler — is abrasive. The gate, the vent land and any narrow restriction see the highest melt velocity and wear out first. A hardened steel with higher HRC, or a replaceable insert in a wear-resistant grade, is the cost-effective answer before the tool is cut.

Mould temperature matters. Glass-Filled wants a mould at 60-40 °C, and a tool designed for a different temperature will run unevenly when set to it. Cooling channels need to be placed where the heat actually concentrates — at thick bosses, at the gate, and where the part joins the runner system — not spread evenly around the cavity. A tool that cools the thin walls and the thick boss at the same rate will hold a flat part and still show a sink mark on the boss.

Applications where Glass-Filled wins

Glass-Filled wins on a specific property such as biodegradability or high purity. It is chosen where the part needs to meet a regulatory or environmental requirement. Common application families include automotive interior and exterior components, appliance and consumer housings, electrical connectors, industrial structural parts and medical device components.

Where Glass-Filled gets replaced is usually clear. When the part has to survive aggressive solvents or continuous UV exposure, a different family takes over. When the temperature ceiling of Glass-Filled is exceeded, a high-temperature polymer steps in. When the resin itself is corrosive — PVC or a flame-retardant grade — the tool steel changes before the resin does.

Design guidelines

  • Wall thickness. Keep nominal walls in the 1.5–3.0 mm range for most grades; thicker walls invite sink and shrink, thinner walls risk incomplete fill. Avoid abrupt thick-to-thin steps.
  • Ribs. Rib thickness around 0.5–0.6 of the adjoining wall keeps the rib from sinking the face. Space ribs so the gaps between them can be cooled and vented.
  • Draft. A minimum of 1° on smooth walls and 1.5–2° on textured walls. Add more where the draw is deep; the part drags most where the texture is deepest.
  • Fillets. A fillet at least 0.5 × wall thickness at internal corners avoids a stress concentration that turns an impact into a crack.
  • Bosses. Use a wall around 0.6 of the nominal wall, add gussets rather than thickening the boss, and keep the boss height under about 2.5 × diameter.

Cost and cycle-time effect

Glass-Filled sits at a premium reflecting its specialty properties or regulatory position. The cost triangle is material price, cycle time and yield. A cycle that is a few seconds shorter on a high-volume part is worth more than the material saving, because the press hour is the dominant cost.

Yield is where the cheap resin can become expensive. Wet resin produces silver streaks and scrap; a cold mould produces weak weld lines that fail in the field; a badly vented tool produces burn marks that need rework. None of these are material costs, and all of them are more expensive than the few percent saved by buying a lower grade.

Common selection mistakes

  • Using a global shrink number without a measurement loop. The nominal allowance is a starting point, not an answer. Correct from the first measured shots.
  • Specifying Glass-Filled outside its temperature ceiling. Service temperature above the rated HDT changes the part behaviour over its lifetime, even if it passes first article.
  • Ignoring abrasion when the resin is filled. A pre-hardened block in a glass-filled job wears at the gate long before it shows bulk wear.
  • Not reading the resin TDS for drying and moisture. Drying is not optional for a hygroscopic grade, and skipping it shows up as a surface defect that looks like a moulding problem.

Veelgestelde vragen

Why does a glass-filled grade move the steel?

Glass fibres erode the gate, the sprue bush and the vent lands before they wear the cavity walls -the velocity and impingement are highest there. A tool that runs unfilled PA at 718H can see a gate wash-out within tens of thousands of shots if you do not move up to a hardened H13 or a replaceable gate insert.

Next step

Moulding this grade?

Send the part and the service condition. We reply with the shrinkage allowance we would cut to, the process window and the steel the resin implies.